Thermal Oil Boilers
THC series, 100,000–1,500,000 kcal/h. Oil-fired and gas-fired models.
- Heat output
- 100,000–1,500,000 kcal/happrox. 116–1,744 kW
- Max. working pressure
- 10 kg/cm²142 psi
- Oil outlet (design basis)
- 260 °C500 °F
- Fuel
- Kerosene, A/B/C heavy oilNatural gas, LPG
Applications
Thermal oil circulates through the system to deliver stable high temperatures at low pressure. Used for process heating, drying, reactors and presses. Combined heating and cooling systems can be designed.

Data needed for sizing
Please include the following in your inquiry:
- Maximum heat loadkcal/h or kW
- Oil inlet and outlet temperatures°C
- Oil volume on the user sideL
- Oil flow on the user sideL/min
- Total system pressure lossUser side and piping, m
- Fuel, thermal oil brand and power supplyVoltage and frequency
Oil-fired standard specifications
| Model THC- | 10 | 20 | 30 | 40 | 60 | 75 | 100 | 125 | 150 |
|---|---|---|---|---|---|---|---|---|---|
| Heat outputkcal/h (kW) | 100,000116 kW | 200,000233 kW | 300,000349 kW | 400,000465 kW | 600,000698 kW | 750,000872 kW | 1,000,0001,163 kW | 1,250,0001,453 kW | 1,500,0001,744 kW |
| Max. working pressurekg/cm² (psi) | 10 kg/cm² (142 psi) | ||||||||
| Fuel use: keroseneL/h | 16 | 31 | 46 | 65 | 97 | 122 | 162 | 203 | 244 |
| Fuel use: A heavy oilL/h | 15 | 29 | 43 | 60 | 89 | 112 | 148 | 186 | 224 |
| Fuel use: B heavy oilL/h | — | 28.5 | 42.5 | 58 | 84 | 106 | 140 | 176 | 211 |
| Fuel use: C heavy oilL/h | — | — | — | — | 80 | 101 | 134 | 168 | 203 |
| Control | ON-OFF | HI-LOW-OFF | |||||||
| Burner fan motorkW | 0.4 | 0.6 | 1.0 | 1.6 | 3.3 | 3.3 | 4.1 | 7.5 | 7.5 |
| Thermal oil flowL/min (US gpm) | 20053 gpm | 32085 gpm | 380100 gpm | 500132 gpm | 800211 gpm | 900238 gpm | 1,100291 gpm | 1,300343 gpm | 1,420375 gpm |
| Pump headm (ft) | 47154 ft | 32105 ft | 45148 ft | 45148 ft | 42138 ft | 45148 ft | 45148 ft | 40131 ft | 55180 ft |
| Circulation pump motorkW | 3.7 | 3.7 | 5.5 | 7.5 | 11 | 15 | 15 | 22 | 30 |
| Oil inlet / outletA | 50 | 65 | 80 | 80 | 100 | 100 | 100 | 125 | 125 |
| Length Lmm | 1,440 | 1,630 | 1,630 | 1,850 | 1,950 | 2,100 | 2,100 | 2,100 | 2,250 |
| Width Wmm | 1,520 | 1,680 | 1,720 | 1,950 | 2,450 | 2,800 | 2,800 | 2,800 | 3,250 |
| Height Hmm | 2,090 | 2,370 | 2,470 | 2,850 | 2,850 | 3,280 | 2,450 | 3,520 | 3,500 |
| Chimney O.D.mm | 220 | 280 | 320 | 350 | 385 | 385 | 480 | 480 | 580 |
Fuel use based on 260 °C thermal oil outlet and 20 °C ambient; kerosene 10,400, A heavy oil 10,200, B heavy oil 9,850, C heavy oil 9,750 kcal/kg. Pump sized for 20–30 °C inlet/outlet difference and 10–25 m system loss. Safety devices: flame detector, oil overheat switch, oil flow differential pressure switch. Power: 3-phase 220 V 50/60 Hz. Natural gas and LPG models available.
Need a quote or technical advice?
Send us your application, capacity, working pressure and fuel. We will recommend a model and quote.