Thermal Oil Boilers

THC series, 100,000–1,500,000 kcal/h. Oil-fired and gas-fired models.

Heat output
100,000–1,500,000 kcal/happrox. 116–1,744 kW
Max. working pressure
10 kg/cm²142 psi
Oil outlet (design basis)
260 °C500 °F
Fuel
Kerosene, A/B/C heavy oilNatural gas, LPG

Applications

Thermal oil circulates through the system to deliver stable high temperatures at low pressure. Used for process heating, drying, reactors and presses. Combined heating and cooling systems can be designed.

Horizontal thermal oil boiler
Horizontal thermal oil boiler
Selection

Data needed for sizing

Please include the following in your inquiry:

  1. Maximum heat loadkcal/h or kW
  2. Oil inlet and outlet temperatures°C
  3. Oil volume on the user sideL
  4. Oil flow on the user sideL/min
  5. Total system pressure lossUser side and piping, m
  6. Fuel, thermal oil brand and power supplyVoltage and frequency
Specifications

Oil-fired standard specifications

Thermal oil boiler oil-fired standard specifications
Model THC-102030406075100125150
Heat outputkcal/h (kW)100,000116 kW200,000233 kW300,000349 kW400,000465 kW600,000698 kW750,000872 kW1,000,0001,163 kW1,250,0001,453 kW1,500,0001,744 kW
Max. working pressurekg/cm² (psi)10 kg/cm² (142 psi)
Fuel use: keroseneL/h1631466597122162203244
Fuel use: A heavy oilL/h1529436089112148186224
Fuel use: B heavy oilL/h—28.542.55884106140176211
Fuel use: C heavy oilL/h————80101134168203
ControlON-OFFHI-LOW-OFF
Burner fan motorkW0.40.61.01.63.33.34.17.57.5
Thermal oil flowL/min (US gpm)20053 gpm32085 gpm380100 gpm500132 gpm800211 gpm900238 gpm1,100291 gpm1,300343 gpm1,420375 gpm
Pump headm (ft)47154 ft32105 ft45148 ft45148 ft42138 ft45148 ft45148 ft40131 ft55180 ft
Circulation pump motorkW3.73.75.57.51115152230
Oil inlet / outletA50658080100100100125125
Length Lmm1,4401,6301,6301,8501,9502,1002,1002,1002,250
Width Wmm1,5201,6801,7201,9502,4502,8002,8002,8003,250
Height Hmm2,0902,3702,4702,8502,8503,2802,4503,5203,500
Chimney O.D.mm220280320350385385480480580

Fuel use based on 260 °C thermal oil outlet and 20 °C ambient; kerosene 10,400, A heavy oil 10,200, B heavy oil 9,850, C heavy oil 9,750 kcal/kg. Pump sized for 20–30 °C inlet/outlet difference and 10–25 m system loss. Safety devices: flame detector, oil overheat switch, oil flow differential pressure switch. Power: 3-phase 220 V 50/60 Hz. Natural gas and LPG models available.

Need a quote or technical advice?

Send us your application, capacity, working pressure and fuel. We will recommend a model and quote.